MyVap
Several methods use the Gas chromatography technique for determining the composition of liquefied petroleum gas (LPG) after a sample expansion. The LPG vaporization is often source of errors and bias. Obtain a representative vapor sample from a pressurized liquefied gas is challenging and difficult to handling. Many procedures are used in laboratories to quantitatively expand LPG samples from a liquid phase to a homogeneous gas phase prior to analysis. Most of them are off-line methods, not safe for operators and environment, user-sensitive, causing lack of reproducibility and repeatability on analysis results. SRA Instruments developed an automated and user-independent LPG Vaporizer to handle under control the critical step of LPG phase change. The heart of MyVap system is the accurate control of the expansion pressure and temperature in a heated reservoir. The vaporization cycle can be programmed easily by the MyVap. Before injection, the vapor is delivered to the GC at a selected pressure.
El sistema MyVAP incluye una bomba de vacío controlada con un microprocesador y un sensor de presió que limpia el camino de muestra antes y después de cada análisis.
Todas las operaciones son totalmente automatizadas por electroválvulas y controladas por un software dedicado vía web. El sistema MyVap está fabricado con componentes de alta calidad de acero inoxidable, incluyendo conexiones seguras y válvulas de purga para una operación segura.
Solamente se tienen que conectar un cilindro de LPG en el sistema MyVap, abrir una válvula de purga líquida durante pocos segundos y presionar un botón verde situado en el panel delantero. El Sistema MyVap realiza los siguientes pasos de manera automatizada, para un análisis rápido y seguro en su de LPG por GC o GC/MS.
| Dimensiones | 450 (L) x 430 (H) x 300 (D) |
| Peso | 15Kg |
| Señal de entrada | 237 VAC, 50 a 60Hz |
| Consumo | Max 6A/220 VAC |
| Material | SS AISI 316 |
| Uso | Interior |
| Comunicación con el GC | Control externo Not ready/ Start / GC ready imput |
| Válvulas | 3 electro válvulas |
| Bomba de vacío interna | Antes de la vaporización limpia todo el camino de muestra |
| Muestras | LPG mezclas C3 y C4 |
| Presión de entrada | Menor a 50 bares |
| Reproducibilidad | Típicamente entre 0,5% para C3 y C4 |
| Programa de control | Software SRA Stand-alone |
| Comunicación con el PC | LAN |
| Sistema operativo |
Internet Explorer rev10, Chrome rev 28 o superiores |
| Aplicaciones | Análisis de composición de LPG |
| Válvula de seguridad | 10 psi |
| Conectores | 1/8" Swagelok para la entrada, 1/16" al GC para la válvula de muestra |
| Temperatura Vaporización |
50ºC - 200ºC (Entrada) y 50 - 100ºC (Cilindro) |
| Rango del sensor de presión |
0-5 bares |
| Modo de operación |
Automático vía software |