OPTIC is a highly advanced Gas Chromatograph multi-mode inlet system with sophisticated temperature and gas flow control that can be used for the most demanding GC analyses. The current version OPTIC-4 can be used for the following injections: 

  • Cold Injections
  • Large Volume Injections
  • Thermal Desorption
  • Pyrolysis (liquid and solid)
  • In-injector Thermochemolysis
  • Cryogenic trap
  • On-column injections
  • Deans’ Switch control
  • GCxGC Modulation control

Starting from Evolution Workstation software version 4.5.1 it is even possible to control a Deans’ Switch or flow modulator with the OPTIC Multi-Mode Inlet.

El diseño patentado del cuerpo del inyector ayuda a tener mejor transferencia de los compuestos desde el inyector a la columna analítica. Este puede ser observado tanto en componentes volátiles como no volátiles.

El inyector Multi modo OPTIC-4 se puede enfriar muy rápido debido a la baja masa térmica. El sistema de inyección puede trabajar desde temperaturas criogénicas (-150ºC) hasta temperaturas muy altas (600ºC) con una rampa de hasta 60ºC/segundo. Con la opción del “Inyector enfriado por Peltier” es posible enfriar más rápidamente y alcanzar temperaturas iniciales de +7ºC.

El OPTIC -4 está diseñado para ser compatible con la mayoría de marcas y modelos GC y GC-MS.

El Sistema OPTIC se compone del inyector, la unidad de control y el software especializado de control Evolution Workstation. Este software muestra gráficamente todos los parámetros del sistema a tiempo real y da la posibilidad de guardar los datos del tiempo de ejecución en cada inyección. El Evolution Workstation puede ser integrado a un Master Lab, MassHunter, Chemstation, Clarity, Analizador, EZChrom y Xcalibur con el software principal Chronos.

Versiones disponibles del Inyector Multi modo OPTIC

El OPTIC-4 puede configurarse en diferentes versiones, las opciones son las siguientes: CrioTrampa, control de flujo electrónico, Control de Presión, refrigeración LN2 o CO2 y también una CrioTrampa independiente. Este puede ser también suministrado con diferentes versiones en la estructura del equipo, desde versiones personalizadas a versiones OEM. Está disponible también una versión especial con un inyector compatible para los tubos estándares de desorción térmica de 1/4” o para liners de tamaños personalizados. Para los inyectores especiales las especificaciones de calentamiento pueden ser diferentes.

Versiones estándares disponibles:

2406-3001 Sistema de inyección OPTIC-4S con un canal único de control electrónico del flujo que incluye el software de control Evolution Workstation.

2406-3002 Sistema de inyección OPTIC-4D con dos canales de control electrónico del flujo que incluye el software de control Evolution Workstation.

2406-3003 Sistema de inyección OPTIC-4SC/LN2 con un único canal de control electrónico de flujo que incluye la opción de la Trampa Criogénica directa al LN2 de refrigeración y el software de control Evolution Workstation. Requiere un tanque de LN2 a alta presión (no incluido).

2406-3004 Sistema de inyección OPTIC-4SC/CO2 con un canal único de control electrónico del flujo que incluye la opción de la Trampa Criogénica CO2 de refrigeración y el software de control Evolution Workstation. Requiere una botella de líquido CO2 (no incluido).

2406-3005 Sistema de inyección OPTIC-4DC/LN2 con dos canales de control electrónico del flujo que incluye la opción de la Trampa Criogénica directa al LN2 de refrigeración y el software de control Evolution Workstation. Requiere un tanque de LN2 a alta presión (no incluido).

2406-3006 Sistema de inyección OPTIC-4DC/CO2 con dos canales de control electrónico del flujo que incluye la opción de la Trampa Criogénica CO2 de refrigeración y el software de control Evolution Workstation. Requiere una botella de CO2 líquido (no incluido).

2406-3007 CryoFocus-4/LN2 Directa al LN2 de refrigeración de la trampa Criogénica del sistema GC sin canal de control electrónico del flujo, incluyendo el software de control Evolution Workstation. Requiere cable de interfase para el GC y el tanque de LN2 a alta presión (no incluido).

2406-3008 CryoFocus-4/CO2 Directa al CO2 de refrigeración de la trampa Criogénica del sistema GC sin canal de control electrónico del flujo, incluyendo el software de control Evolution Workstation. Requiere cable de interfase para el GC y la botella de CO2 líquido (no incluido).

Los sistemas se suministran sin el hardware ni instalación.

Especificaciones del OPTIC-4

General:
- Dimensiones: 34cm x 14cm x 34cm (Alto x Ancho x Fondo), Peso: 6.7Kg (controlador)
- Rango de Temperatura ambiente de funcionamiento: 18°C – 40ºC
- Humedad ambiente de funcionamiento: 40 – 70% - Red eléctrica: 100 - 240VAC, 50-60Hz
- Consumo de energía típico: 150W, consume máximo de energía: 450W
Inyector:
- Completo control de flujo electrónico y presión
- Temperatura máxima de funcionamiento: hasta 600ºC
- Refrigeración: aire (< 35ºC), LCO2 (< -50ºC), LN2 (< -150ºC)
- Rango de rampa de temperatura : 1 – 60ºC/segundos
- Pueden usarse diferentes tipos de septum: Merlin Microseal, Septum de 11mm o septum tipo tapón para el inyector.
EFC:
- Control electrónico completo en la columna, split y flujos de purga de septum
- Rango de presión: 7 – 700kPa
- Rango del flujo total: 5 – 500ml/min He (Canal principal), 1 – 100ml/min He (Únicamente en el Canal auxiliar OPTIC-4D)
- Sensor de presión: Precisión: 1% escala completa, repetibilidad: 0.2% escala completa
- Sensores del flujo: Precisión: 1% escala completa, repetibilidad: 0.2% escala completa
- He, N2 o H2 como gas portador a una presión máxima de 700kPa
- Sensor de desorción en el split liner

Interfases:
- LAN y USB
- Cuatro salidas auxiliares (30V/ 500mA máx.)
- Una salida puede utilizarse para el control de modulación
- Control remoto de arranque y detención del GC y automuestreador
Software:
- Permite definir y desarrollar el método y la secuencia
- Indicador de estado del sistema en tiempo real
- Genera automáticamente secuencias de optimización
- Control directo del instrumento en el modo de espera
- Archivo de registro de ejecución del Sistema
- Protección por contraseña con dos niveles de acceso
- Hasta nueve programas de rampas de temperatura que incluyen temperaturas negativas
- Calculadora de optimización flujo/presión
- Control Dean’s Switch
- Control de modulación
Opción Trampa Criogénica:
- Rango de temperatura de funcionamiento: - 150ºC a + 350ºC
- Rango de la rampa de temperatura: 1 – 60ºC/segundos
-Refrigeración: LN2 desde el tanque presurizado (150 – 200kPa)

A Novel Large Volume At-Column Concentrating Technique and its Applicability to Labile Pesticide Analysis A Novel At-Column.pdf A Simplified Method for the Determination of Atmospheric Hydrocarbons.pdf Analysing Low Volatility Samples using High Temperature PTV Injection.pdf Analysing Quaternary Ammonium Salts (QAS) in Seawater by Difficult Matrix Introduction (DMI).pdf Analysis of 3-MCPD Esters in Edible Oils Using LVI Coupled to Comprehensive GC-TOF.pdf Analysis of Ethylene Glycol in Wastewater by Direct Aqueous Injection.pdf Analysis of Lambda-Cyhalothrin using the At-Column Concentrating AT-Column technique.pdf Analysis of Aroma Compounds in Cheese.pdf Analysis of difficult to retain components using OPTIC Multimode Inlet with OPTIC Cooler.pdf Analysis of Semi-Volatile Organics According to EPA Method 8270.pdf Analysis of the Nicotine content in Tobacco by Direct TD-GC-MS.pdf Analysis of Trace Level Silicone Oil in Vehicle Paint using Difficult Matrix Introduction (DMI) Coupled with Selective Exclusion.pdf Applications of PTV Injectors for Problem Solving in the Petrochemical Industry Part I. Thermal Desorption with GC&GC-MS.pdf Automated Determination of Fatty Acid Methyl Ester and Cis-Trans- Methyl Ester Composition of Fats and Oils.pdf Automating the Analysis of Mineral Oils in Water According to ISO-DIS 9377-4 Using the Focus Sample Processing Robot.pdf Automated fatty acid profiling of raw algae’s by THM-GC-MS.pdf Automating the Analysis of Selected Phenols Using The Focus Sample Processing Robot.pdf Atmospheric Monitoring of Volatile Organic Compounds Using Programmed Temperature Vaporisation Injection.pdf Characterization of paint from artwork with automated THM and OPTIC Injector.pdf Characterisation of Polymers by Multi-Step Thermal Desorption-Programmed Pyrolysis Gas Chromatography Using a High Temperature PTV Injector.pdf Comparison of two GC-columns for analysis of pesticides for the US EPA 8270 method, Rtx-5MS and Inertcap-pesticides.pdf Combined Thermal Desorption and Pyrolysis GC Using a PTV Injector Part II. Polymer Characterization.pdf Combined Thermal Desorption and Pyrolysis GC Using a PTV Injector Part I. Theory & Practical Aspects.pdf Determination of Breakthrough Volume for Optic Liners.pdf Direct Thermal Desorption Using the Optic Injector.pdf Determination of TPH in Water using SPE-DEX® and LVI-GC-FID.pdf Environmental Applications of Large Volume Injection in Capillary GC Using PTV Injectors.pdf Evaluation of the Programmed Temperature Vaporiser for Large Volume Injection of Biological Samples in Gas Chromatography.pdf Determination of N-cyclohexyl-diazeniumdioxide (HDO) Containing Compounds in Treated Wood Using GC-MS.pdf Fast Analysis of Chlorinated Priority Pollutants Using Large Volume Injection.pdf Fast Analysis of Organophosphorus Pesticides in a Complex Food Matrix.pdf Fully Automated Preparation & Analysis of Fatty Acid Methyl Esters Using the Focus Sample Processing Robot.pdf Fully automated analysis of 549 pesticides in oil with LCxGC and FOCUS auto sampler.pdf High Throughput Multi-Residue Screening of Drinking Water using the SPE-DEX~ and Pegasus GC-ToFMS.pdf Heating up Simulated Distillation.pdf High-Speed Isothermal Analysis of Atmospheric Isoprene and DMS Using On-Line Two-Dimensional Gas Chromatography.pdf In-Liner Derivatisation and LVI-GC-MS of THC in Human Hair.pdf Large Volume Injection in Gas Chromatographic Trace Analysis Using Temperature Programmable (PTV) Injectors.pdf Inlet Derivatisation for the GC Analysis of Organic Acid Mixtures.pdf Large Volume Injection in Capillary GC Using PTV Injectors, Comparison of Inertness of Packing Materials.pdf Large Volume Injection of Organochlorine Pesticide Extracts Using a Programmable Temperature Vaporiser in the Solvent Split Mode.pdf Large Volume Injections in Hyphenated Systems for Waste Water Analysis.pdf Large Volume Oil in Water.pdf Large Volume Sample Introduction in Capillary Gas Chromatography.pdf Large Volume Sample Introduction Using Programmed Temperature Injector Systems.pdf Measurement of Low Levels of Cotinine in Saliva.pdf Modeling an Optic 2 as an Alternative to Multidimensional Chromatography.pdf In-Situ Field Measurements of Isoprene, Its Oxidation Products & Selected Monoterpenes in a Eucalyptus Forest.pdf Multi-Residue scanning for Pesticides in Fruit and Vegetables Using On- Line Clean-up GC-MS.pdf Nitrile Rubber Analysis Using the Optic 2 Programmable Injector.pdf MDGC system for investigation of fragrance components.pdf Pesticide and Other Environmentally Relevant Substances that can be Analysed by Rapid Large Volume.pdf Petrol Range Organics In Soils, Sludges And Wastewaters by Headspace GC-MS.pdf Pressurised Liquid Extraction of PAHs from Soil and Sediment Samples.pdf Pyrolysis of solid PE and PPSU with OPTIC 3 - GC-MS.pdf Pyrolysis ramp rate comparison with Polystyrene and Polycarbonate.pdf Quantative analysis of allergens in cosmetics with GC-MS.pdf Reduction of Endrin and DDT Breakdown Using a PTV Injector.pdf Selecting the Injection Mode in Capillary Gas Chromatography.pdf Sub-ppt Atmospheric Measurements Using PTV-GC-FID & Real-Time Digital Signal Processing.pdf Testing the Performance of the Focus Direct-TD with Real Samples.pdf Simplified Gas-Chromatographic Procedures for the Determination of C1-C7 Hydrocarbons in Urban Atmospheres.pdf The Analysis of High Molecular Weight Polymer Additives Using the AT-Column.pdf The Analysis of Acid Herbicides by RLVI-GC-MS.pdf The Analysis of Mineral Oil in Sunflower Oil.pdf The Analysis of Organophosphorous Pesticides by Large Volume Injection.pdf The Analysis of Pyrethroids using the AT-Column Concentrating Technique.pdf The Analysis of Organotin Compounds in Water by GC-MS Using Large Volume Injection.pdf The Automated On-Line Sampling and Analysis of Glycerol in Biodiesel.pdf The Automated Sample Preparation and Analysis of a Pharmaceutical Cream using the Focus Sample Processing Robot.pdf The Determination of Allergens in Cosmetics using GCXGC(qMS).pdf The Flavour Analysis of Yoghurt by Solid Sorptive Extraction and Direct Thermal Desorption-GC-MS.pdf The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques.pdf The Large Volume Aqueous Injection of a Parent Amino Acid Extract.pdf Rapid Large Volume Injection-GC-MS Analysis of Pesticides in Food Prepared by the QuEChERS method.pdf The On-line VOC Analysis of Industrial Effluents using Ambient Headspace.pdf The Thermal Desorption of Chocolate Flavoured Powder using Difficult Matrix Introduction(DMI).pdf The Role of Selective Exclusion in the Analysis of Specific Hydrocarbons in n-Alkane Waxes.pdf The Vision Automated Solid Phase Extraction System for Triazine Herbicides at ng-L Levels in Drinking Water.pdf Time Course of the Emission of Volatiles from Damaged Broad Bean Leaves.pdf Trace Analysis of Drugs by AT-Column Concentrating Large Volume Injection-GC-MS.pdf TPHs in Wastewaters using the Focus Robotic Sample Processor.pdf Use of Temperature Programmable Injector in Static & Dynamic Headspace Analysis of Aroma Volatiles.pdf The Thermal Desorption-Pyrolysis of Glass Fibre Air Filters.pdf VOC´s in water, advantage of a cryotrap.pdf VOC´s in water, advantage of a cryotrap.EPA624.pdf