Skip to Content

5975T LTM GC/MS

When you need fast and accurate results in the field, the Agilent 5975T LTM GC/MSD can deliver the same high performance, reliability and quality of analysis as our bench top 5975C series GC/MSD. The 5975T system is the first transportable commercial GC/MSD system that can provide credible results on the ground without any lab-based analysis required.

The system is a third smaller and consumes about half the power of our bench top option, enabling operators to quickly and efficiently provide the credible results needed to make vital health and safety decisions. The 5975T system utilizes Agilent’s proprietary LTM technology for direct, rapid heating and cooling, enabling faster on-site analysis across a wide mass range. Check our web www.yourmobilelab.com for the integration of these systems in our mobile units.

 

  • 1.8u to 1050u mass range for the greatest range of applications

  • Transportable and highly reliable for quick response in the field.

  • Proprietary LTM technology allows for direct, rapid heating (up to 1200°C/min) and cooling for faster on-site analysis

  • Gold true hyperbolic quartz quadrupole provides unsurpassed performance and reliability for on-site measurement

  • Classical EI spectra using quadrupole technology delivers NIST searchable spectra of unknowns

  • 7667A Mini Thermal Desorber lets you perform fast, confident gas sample introduction in the field

  • Thermal Separation Probe(TSP) – A fast and easy alternative MS probe for analyzing solid, liquid, and slurry samples in the field

  • Handheld Capillary Trap Gas Sampler (CTS) puts air sampling at your fingertips – no matter where your analysis takes you

  • Agilent’s 7693 Series and 7650A Automatic Liquid Sampler (ALS) deliver the fastest injection times of any GC autosampler

  • Excellent value for money with one system for both lab and field use

Analysis of permanent gases and light hydrocarbons using Agilent 7820A GC with 3-valve system.pdf A Turn-key Analyzer Solution for the Target Based Screening of Environmental Water.pdf An Economical EN71 Solution for VOCs Analysis from Toys Emission Using an Agilent 7667A Mini TD and an Agilent 5977E MSD System.pdf Analysis of EPA Method 8270D Semivolatiles Using the Agilent J&W DB-UI 8270D Ultra Inert GC column.pdf Analysis of Trace Hydrocarbon Impurities in Benzene by Agilent 7820A Gas Chromatograph.pdf Analysis of Volatile Organic Compaunds in Environmental Waters.pdf Analysis of Volatile Organic Compunds in Environmental Waters Using the Agilent 7697A Headspaces and 7890B-5977A GC-MS.pdf Analyze Pesticides in Water with Stir Bar Sorptive Extraction and Thermal Separation.pdf Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC-MS.pdf Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC.pdf Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC-MSD.pdf Environmental Volatiles Using an Agilent 7697A Headspace Sampler, an Agilent 7890B GC, and an Agilent 5977A Series GC-MSD.pdf EPA Method 8270 for SVOC Analysis on the 5977A Series GC-MSD.pdf Fast Method for Determination of Nitrobenzene in Water using Agilent 5975T LTM GC-MSD.pdf High Sensitivity GC-MS-MS Analysis of Nonpolar Organic Compounds in Water Using the Agilent 7000 Triple Quadrupole GC-MS.pdf Impact of Air Leaks on the productivity of GC and GC-MS Systems.pdf MTBE Residue in Environmental Water and Soil Analysis by Agilent 7820 GC-FID.pdf Paraffins, Naphthenes and Aromatics (PNA) in Hydrocarbon Streams with the PIONA+ Analyzer.pdf Rapid and Sensitive Determination of Airborne N-Nitrosamines Using the Agilent Capillary Trap Sampler, Thermal Separation Probe, and an Agilent 5975T LTM GC-MS.pdf Rapid Field Sampling of Airborne Compounds Using the Capillary Trap Sampler, Thermal Separation Probe, and an Agilent 5975T LTM GC-MS.pdf TDTS Technical Note 16. Round-the-clock, on-line and cryogen-free monitory of hydrocarbons from acetylene to trimethylbenzene in ambient air.pdf TDTS Technical Note 28. Optimising Analytical Performance and Extending the Application Range of Thermal Desorption for Monitoring Air Indoors and Inside Vehicle Cabins.pdf TDTS Technical Note 47. The Analysis of Landfill Gas Compounds using Thermal Desorption GC-MS and a Retention Time Locked Database.pdf TDTS Technical Note 79. Air monitoring – The respective advantages and applications of canisters and tubes.pdf TDTS Technical Note 80. Evaluation of a “Soil Gas” sorbent tube for improving the measurement of volatile and semi-volatile fuel vapors in soil contaminated land.pdf TDTS Technical Note 81a. Analysis of canister air samples using cryogen-free thermal desorption in compliance with US EPA method TO-15.pdf TDTS Technical Note 99. Using the CIA Advantage for automated cryogen-free analysis of canister air and gas.pdf

Fast Refinery Gas Analysis System Based on the Agilent 7890B GC System and G3507A Large Valve Oven Using Micropacked Columns.pdf Packed Column Refinery Gas Analysis System Based on the Agilent 7890B GC System and G3507A Large Valve Oven.pdf A New Approach to ASTM D3606 for the Analysis of Benzene and Toluene in Gasoline using Mid-Column Backflush and Hydrogen Carrier with the Agilent 7890B GC.pdf Agilent 7890 Series GC with Prefractionator for Reliable Analysis of Crude Butadiene and Mixed C4 Streams.pdf An Improved Flame Photometric Detector for the Analysis of Dibenzothiophenes in Diesel, Distillates, and Feedstocks Using the Agilent 7890B Series GC.pdf Analysis of Dissolved Gas in Transformer Oil by Gas Chromatography using a Stripper Column.pdf Analysis of USP -467- Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph.pdf Applying the Agilent 5977A MSD to the Analysis of USP-467- Residual Solvents with the 7697A Headspace Sampler and 7890B GC.pdf Determination of Formic Acid in Acetic Acid for Industrial Use by Agilent 7820A GC.pdf Determination of Total FAME and Linolenic Acid Methyl Esters in Biodiesel According to EN-14103.pdf Improving Efficiency in the Forensics Laboratory. Introducing a New Controlled Substances Analyzer.pdf Paraffins, Olefins, iso-Paraffins, iso-Olefins, Naphthenes and Aromatics (PIONA) in Hydrocarbon Streams.pdf Single Detector Deans Switch Natural Gas Analysis with Resolution of Oxygen and Nitrogen.pdf

3-in-1 Solution for Mobile Forensic Applications.pdf A Blind Study of Pesticides in Vegetables by Bond Elut QuEChERS Extraction Kits and Agilent 5975T LTM GC-MSD.pdf A Rapid Method for Detection of Drugs of Abuse in Blood Samples Using the Thermal Separation Probe and the 5975T LTM GC-MS.pdf Accelerated Analysis of On-Site Pesticide Detection in Vegetables by Agilent 5975T LTM GC-MSD and TSP.pdf Agilent Inert Flow Path Enhancements Improve Drugs-of-Abuse Testing.pdf Analysis of Carcinogenic Tobacco- Specific Nitrosamines in Mainstream Cigarette Smoke Using an Agilent J&W DB-35ms Ultra Inert GC Column.pdf Analysis of Ethanol in Blood with the Agilent 7820A GC and 7697A Headspace Sampler.pdf Analysis of Fatty Acid Methyl Esters by Agilent 5975T LTM GCMS.pdf Analysis of Fruit and Vegetable Pesticides by GC-MS-MS Using Agilent Inert Flow Path.pdf Analysis of N-nitrosodimethylamine (NDMA) in Water using GC Triple Quadrupole Mass Spectrometry.pdf Analysis of Nitrosamines in Drinking Water Using the Agilent 5977A Series GC-MSD System.pdf Analysis of Organochlorine Pesticides in Drinking Water by Agilent 7820 Gas Chromatograph-Micro-Electron Capture Detector.pdf Analysis of preservative additives in food by Agilent 7820A GC.pdf Analysis of Volatile Halogenated and Aromatic Hydrocarbons in Water with a Versatile Agilent 7890B Gas Chromatography System and an Agilent 7697A Headspace Sampler.pdf Assessing Washing Methods for Reduction of Pesticide Residues in Tomatoes and Other Produce Using LC-MS and GC-MS.pdf Automated Sample Preparation for FAME Analysis in Edible Oils.pdf Characterization and Classification of Heroin from Illicit Drug Seizures.pdf Chemometric Profiling of Whiskey Using the 5977A GC-MSD.pdf Cooperation with the China Academy of Urban Planning and Design for Field VOC Measurement of Drinking Water Sources with the Agilent 5975T LTM GC-MSD.pdf Detection of Chemical Warfare Agents by Transportable GC-MS.pdf Determination of Fatty Acid Methyl Esters in Milk.pdf Determination of Semivolatile Organic Compounds in Drinking Water Using the Agilent 5977A Series GC-MSD.pdf EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC-MSD with Static Headspace.pdf Ethyl glucuronide determination in hair as an indicator of chronic alcohol abuse.pdf Fast Analysis of Fire Debris Using an Agilent 5975T LTM GC-MSD with Capillary Trap Sampling (CTS).pdf Identification of Flavor and Fragrance Allergens in Some Common Snack Foods Using Transportable Agilent 5975T GC-MS.pdf Lowering Detection Limits for Routine Analysis of Pesticides Residues in Foods Using.pdf Pesticides Analysis Using the Agilent 5977A Series GC-MSD.pdf Quantitation and Confirmation of Blood Ethanol Content using a New GC-FID-MS Blood Alcohol Analyzer.pdf Screening Foodstuffs for Pesticides and Other Organic Chemical Contaminants Using Full Scan GC-MS and Mass Hunter Quant Target Deconvolution.pdf Screening PAHs in Soil Using RTL Database with Bond elut QuEChERS Extraction Kits and Agilent 5975T LTM GC-MS.pdf Sensitive and Reproducible Detection of PAHs Using the Agilent 5977A Series GC-MSD.pdf Targeted Exposomics.Profiling Urinary Organic Acids.pdf Sensitive and Reproducible Phthalate Analysis Using the Agilent 5977A Series GC-MSD.pdf